Fire Alarm bids in Utah and Wyoming

Simplex Fire Alarm bids

Contact Larry Love at 801 898 6003 Larry.Love@jci.com for new construction pricing or remodels

Matthew Bingham 801 419 1379 matthew.bingham@jci.com TI new construction

Jackson Jones for Simplex service 801 403 3461 jackson.jones@jci.com

Call Shandie Gorney 801 214 5668 shandie.a.gorney@jci.com for Simplex fire alarm service calls

She can also help you with test and inspection pricing, monitoring, fire extinguisher certification.

If you need a service call set up right away call our local number 801 262 9406 option 1

Please send us your plans, specifications and bid dates and times as soon as you can so we have enough time to get the pricing done for you.

Once we have pricing put together we will send you a proposal

We will need a new customer application filled out and a W9 form in order to get your company into our system. We will also need the DWG drawings so we can have our designers being the design and submittals.

Plan on 3 or 4 weeks after we get a signed proposal or PO in order to get the CAD drawings done and submitted to the City so we can get 3rd party reviews when needed and fire marshal approval.

Plan on a 15% mobilization fee so we can get equipment ordered and the job on the schedule.

Make sure you give us any time tables that need to be met we will need to plan ahead to try and accommodate your schedule.

We will need to know if the job will be done in phases or if it will be one phase.

The Electrical Contractor will need to do the conduit, high voltage work, providing and installing the proper FPL, FPLP or FPLR fire wire.

Johnson Controls Fire Protection JCFP will do the programming, testing and certification of the fire alarm system.

In the bidding process we strive to notify you of issues from the bid documents that need to be addressed in order to avoid change orders such as items missing from the plans that will be needed to meet code or fire marshal approval.

Often the PE Electrical Engineer will put a statement on the plans that says the fire alarm system will need to be designed to meet code and local fire marshal requirements. They do this although often they miss items on the plans so what we strive to do is to provide you with a price as per the drawings and what is shown on the plans and sometimes we give you an ADD ALT to meet code.

Many companies will bid what is on the plans and then try to get changes approved later on.

Items in the specifications such as 5 year warranties or special 2 year software update agreements or additional spare equipment will add to the cost of the project so if value engineering is needed let us know because sometimes the engineer will put things in the specification that are not required and not needed which makes the price go way up when the job could be done for less.

Know that many projects require systems that are more complex than others and Simplex is built for doing things that many other systems cannot do such as the tie in to 100 suppression systems into one Simplex 4100ES panel when no other panel can do this. For this reason and many others Simplex is a preferred brand for Airports because we can Network thousands of points together effectively and our systems can tie into Smoke Control and be programmed to do things that other panels cannot such as the installation of addressable Speaker Strobes and Horn Strobes allowing testing to be done quickly without downtime.

Contact Larry Love at 801 8 98 6003 Larry.Love@jci.com for more information or with corrections to this information. Larry is an employee of Johnson Controls Fire Protection and a NICET level 2 Fire Alarm tech #107204 through National Institute of Engineering Technologies.

Foundation Series entry level competitive with lower end fire alarm systems

4007ES Midrange fire alarm system that can be conventional and or addressable up to 250 points

4017ES Midrange addressable fire alarm system with Voice Evacuation built into the main panel

4010ES Upper range- up to 1000 points

4100ES This panel can expand to thousands of pints - up to 3000 points and up to 100 suppression panels


Contractors, Commercial, Electrical ContractorsLarry LoveJohnson Controls Fire Protection LPSimplex, Simplex Fire Alarm, Johnson Controls, JCI, Johnson Controls Fire Protection, Estimator, Larry Love, Matt Bingham, Shandie A Gorney, Johnson Controls Fire Protection LP, Fire Alarm, Simplex Grinnell, Simplexgrinnell, 4100, 4100U, 4100ES, Utah, Salt Lake City, Salt Lake City Utah, bids, Fire Alarm bids, Fire Alarm estimate, Fire Alarm Design, Design fire alarm systems, Who do I call for Fire Alarm, Who do I call for fire alarm in salt lake city, Who is the local Simplex, number for the local Simplex, Airport fire alarm systems, Hospital Fire Alarm System, Who do I call for fire alarm service, where to do I buy Simplex Fire Alarm, Addressable Horn Strobes, Addressable Notification, Best Fire Alarm, Most advanced fire alarm, Area of refuge, AOR, Mass Notification, Voice Evacuation, VESDA, CORNELL, Rath, Talk a Phone, Sprinkler Service, Fire Alarm Test and Inspections, UL listed Monitoring, Monitoring, Oldest Fire Alarm Company, National Simplex Dealer, Simplex Dealer, Who do I call, Where do I buy, Duct Detectors, CAD, Smoke Detectors, Pull Stations, Manual Pull Boxes, Manual box, Monitor Modules, Foundation Series, Relays, CM, R, 4906-9101, 4906-9127, JCI.com, 4100ES Fire Control Unit, 4007ES, 4007ES Fire Control Units, 41010ES Fire Control Unit, 4009 IDnet, NAC, MAPNET, UL864, UL 2017, ULC-S527, ULC/ORD-C100, ULC, NFPA 72, IBC, IFC, NEC, Fire Marshal, 4120 Fire Alarm, 4120, DACT, Truesite, Truesite workstation, SCU/RCU, Annunciator, SafeLINC, 4009 IDNAC, batteries, Industrial, Code Compliant, NFPA 72 Fire Alarm, Simplex Estimates, Simplex bids, Simplex Estimator, Utah Simplex Estimator, Larry G Love, Larry G. Love, LarryLovesUtah.com, datarooms, data facilities, data centers, data center, Airport Fire Alarm, Shane Thompson, Calvin Oaks, Chris Limberg, Chris Limburg, NEO, Brivo, kantech, DMP, Qolsys, Exact Vision, Milestone, Digital Watch Dog, DSC, fire extinguishers, fire sprinklers testing, IDNET, IDnet, oxygen replenishment, BDA, Emergency responder radio, who is the local Simplex representative in my area, who is the local Simplex salesman in Utah, Who is the local Salesperson in Utah, Jackson Jones, CO, Carbon Monoxide, 8012629406, 801 262 9406, 801 214 5668, 8014033461, 801 403 3461, 801 898 6003, 8018986003, 8014191379, 801419 1379, CO2, Carbon Dioxide, NASPO, State Contract, CS Gateway, Safe Linc, 4017Comment